Vehicle & Off-Highway Machinery Control Systems (M-Series)
DSEM240
CAN Slave Unit
49 mm x 240 mm x 190 mm (H x W x D)
1.46" x 9.45" x 7.48" (H x W x D)
WEIGHT
<1.5 kg
PRODUCT VARIANTS
M240-01 - M240 CAN Slave Unit (J1939)
M240-02 - M240 CAN Slave Unit (CAN Open)
Request a Quote
Product Highlights
Key Features
Key Benefits
Specification
DC SUPPLY
8 V DC to 32 V DC
CURRENT CONSUMPTION
OPERATING CURRENT
<300 mA at 24 V without external loads
TOTAL INPUTS/OUTPUTS
44 (20 inputs / 24 outputs)
INPUTS
Configurable
Digital inputs (active high/active low)
Analogue inputs voltage 0 V to 5 V, 0 V to 10 V, 0 V to 32 V current 4 mA to 20 mA, Ratiometric, Resistive, Frequency, Pulse Count
OUTPUTS
Configurable
2 A / 4 A
Digital Output High-Sided, Low-Sided PWM, PWMi
INTERFACES
CAN 1
J1939 or CAN Open
DIMENSIONS
37 mm x 240 mm x 190 mm (H x W x D)
1.46 " x 9.45 " x 7.48 " (H x W x D)
WEIGHT
<1.5 kg
STORAGE TEMPERATURE RANGE
-40 ˚C to +85 ˚C
-40 ˚F to +185 ˚F
OPERATING TEMPERATURE RANGE
-40 ˚C to +85 ˚C
-40 ˚F to +185 ˚F
(at full load)
PROTECTION RATING
IP67 (with mating connectors)
MOUNTING
4 x M6 bolts
Environmental Testing Standards
EN 61000-6-2
EN 61000-6-4
EN 61010
Electromagnetic compatibility (EMC) noise immunity
Electromagnetic compatibility (EMC) emission standard
Safety requirements for electrical equipment for measurement, control and laboratory use
E11 MARKING (PENDING)
UN/ECE-R10
Emission standard noise immunity with 100 V / m
ELECTRICAL TESTSISO 7637-2 (2004 E)
ISO 16750-2 (2012 E)
Pulse 1, severity level: III; function state C
Pulse 1, severity level: IV; function state C
Pulse 2a, severity level: IIII; function state A
Pulse 2a, severity level: IV; function state A
Pulse 2b, severity level: III; function state C
Pulse 2b, severity level: IV; function state C
Pulse 3a, severity level: III; function state A
Pulse 3b, severity level: III; function state A
Pulse 3b, severity level: IV; function state A
Pulse 4, severity level: III; function state A
Pulse 4, severity level: IV; function state A
Pulse 5a, severity level: III; function state A
Pulse 5a, severity level: IV; function state A
EN 60068-2-1
EN 60068-2-2
EN 60068-2-30
EN 60068-2-38
EN 60068-2-78
Cold test, 96 hours unpowered minimum storage temperature. Increase to minimum operating temp 5 hours power cycle (50% duty cycle)
Dry heat, 96 hours operational at maximum operating temp
Temp & humidity cyclic test, 18 hours unpowered maximum storage temperature. Decrease to maximum operating temp 5 hours power cycle (90% duty cycle)
Damp heat, cyclic 25/55 ˚C 95% RH - 6 cycles
Damp heat, steady state test temperature 40 ˚C / 93% RH test duration: 21 days
Temperature cyclic test
MECHANICAL TESTS
ISO 16750-3
EN 60068-2-6
ISO 16750-3
Test VII; vibration, random mounting location: vehicle body. Vibration, sinusoidal 10...500 Hz; 0.73 mm / 10 g: 10 cycles / axis.
Bumps 30 g / 6 ms; 24,000 shocks