Auto Mains (Utility) Failure Control Modules
DSE4420
Auto Mains (Utility) Failure Control Modules
The DSE4420 Auto Mains (Utility) Failure Control Module provides 3 phase sensing, automatic switchover between mains and generator power and a number of operating and monitoring features for single diesel and gas generating sets.
OVERALL SIZE
180 mm x 116 mm x 42 mm (7.1” x 4.6” x
1.7”)
PANEL CUTOUT SIZE
154 mm x 98 mm (6.0" x 3.9")
MAXIMUM PANEL THICKNESS
8.0 mm (0.3”)
Request a Quote
Product Highlights
Key Features
Key Benefits
- Additional Features
- CAN & magnetic pick-up variants (specify type when placing order).
- Over speed protection.
- Manual/remote start.
- Hours counter.
- LED status indication.
- Large back-lit icon LCD display.
Specification
DC SUPPLY
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
CRANKING DROPOUTS
Able to survive 0 V for 50 mS, providing supply was at least 10V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.
MAXIMUM OPERATING CURRENT
150 mA at 12 V, 80 mA at 24 V
MAXIMUM STANDBY CURRENT
50 mA at 12 V, 30 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
OUTPUTS
OUTPUT A (FUEL)
2 Amp DC at supply voltage
OUTPUT B (START)
2 Amp DC at supply voltage
AUXILIARY OUTPUTS C,D,E,F
2 Amp DC at supply voltage
MAINS (UTILITY) VOLTAGE RANGE
15 V - 333 V AC (L-N)
FREQUENCY RANGE
3.5 Hz to 75 Hz
GENERATOR
VOLTAGE RANGE
15 V - 333 V AC (L-N)
FREQUENCY RANGE
3.5 Hz to 75 Hz
MAGNETIC PICK UP
VOLTAGE RANGE
+/- 0.5 V to 70 V
FREQUENCY RANGE
10,000 Hz (max)
Environmental Testing Standards
ELECTRO-MAGNETIC COMPATIBILITY
BS EN 61000-6-2
EMC Generic Immunity Standard for the Industrial Environment.
BS EN 61000-6-4
EMC Generic Emission Standard for the Industrial Environment.
ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment, including Electrical Business Equipment.
TEMPERATURE
BS EN 60068-2-1
Ab/Ae Cold Test -30°C.
BS EN 60068-2-2
Bb/Be Dry Heat +70°C.
VIBRATION
BS EN 60068-2-6
Ten sweeps in each of three major axes.
5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn.
HUMIDITY
BS EN 60068-2-30
Db Damp Heat Cyclic 20/55° C @ 95% RH 48 Hours.
BS EN 60068-2-78
Cab Damp Heat Static 40° C @ 93% RH 48 Hours.
SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes 15 gn in 11 ms.
DEGREES OF PROTECTION PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the control panel with the optional sealing gasket.
Connection Diagram
Product Variants
4420-01 - 4420 3PH AMF MPU FREQUENCY
4420-02 - 4420 3PH AMF CAN FREQUENCY